Connecting Devices to a Control or Expansion Hub

cynergyou edited this page Apr 9, 2019 · 12 revisions

This section demonstrates how to connect and configure devices to your REV Robotics Expansion Hub. For the examples in this document, we will connect the Expansion Hub through a switch to a 12V battery. We will then connect a DC motor, a servo and some sensors to the Expansion Hub.

Connecting 12V Power to the Expansion Hub

The Expansion Hub draws power from a 12V rechargeable battery. For safety reasons, the battery has a 20A fuse built in. A mechanical switch is used to turn on/turn off the power.

Note that it will take an estimated 5 minutes to complete this task.

Connecting 12V Power to the Expansion Hub
1. If your 12V battery has a Tamiya style connector, connect the Tamiya to XT30 adapter cable to the matching end of the switch cable.


Do not plug connect the 12V battery to the Tamiya adapter yet. We will connect the battery during a later step.
2. Connect the other end of the switch cable to a matching XT30 port on the Expansion Hub.

3. Verify that the switch is in the OFF position.

4. Connect the 12V battery to the Tamiya to XT30 cable.

5. Turn on the switch and verify that the Expansion Hub is drawing power from the battery. Note that the Expansion Hub’s LED should be illuminated (notice the blue LED in upper right-hand corner of the Expansion Hub in the image below).

6. Turn off the switch and verify that the Expansion Hub is off. Note that the Expansion Hub’s LED should not be illuminated.

Connecting a Motor to the Expansion Hub

The Expansion Hub can drive up to four (4) 12V DC motors per Expansion Hub. The Expansion Hub uses a type of electrical connector known as a 2-pin JST VH connector. Currently, the FIRST-approved 12V DC motors are equipped with Anderson Powerpole connectors. An adapter cable is used to connect the Anderson Powerpole connectors to the Expansion Hub motor port.

For the examples in this wiki, FIRST recommends that the user build a simple rig to secure the motor in place and prevent it from moving about during the test runs. The image above shows a Tetrix motor installed in a rig built with a Tetrix motor mount and some Tetrix C-channels. A gear was mounted on the motor shaft to make it easier for the user to see the rotation of the shaft.

Note that it will take an estimated 2.5 minutes to complete this task.

Connecting a 12V Motor to the Expansion Hub
1. Connect the Anderson Powerpole end of the motor’s power cable to the Powerpole end of the Anderson to JST VH adapter cable.

2. Connect the other end of the Anderson to JST VH adapter cable into the motor port labeled “0” on the Expansion Hub.

Connecting a Servo to the Expansion Hub

The REV Robotics Expansion Hub has 6 built-in servo ports. The servo ports accept the standard 3-wire header style connectors commonly found on servos. Note that ground pin is on the left side of the servo port.

Note that it will take an estimated 2.5 minutes to complete this task.

Connecting a Servo to the Expansion Hub
1. Connect the servo cable to the servo port labeled “0” on the Expansion Hub. Note that the ground pin is on the left side of the servo port.

2. Verify that the black ground wire of the servo cable matches the ground pin of the servo port (which is aligned on the left side of the port).

Connecting a Color-Distance Sensor to the Expansion Hub

The Expansion Hub has 4 independent I2C buses. Each bus has its own port on the Hub. We will connect a REV Robotics Color-Distance sensor to the I2C bus #0 on the Expansion Hub.

Note that it will take an estimated 2.5 minutes to complete this task.

Connecting a Color-Distance Sensor to the Expansion Hub
1. Connect the one end of the 4-pin JST PH cable to the REV Robotics Color-Distance sensor.

2. Plug the other end of the 4-pin JST PH cable to the I2C port labeled “0” on the Expansion Hub.

Connecting a Touch Sensor to the Expansion Hub

The Expansion Hub has 4 independent digital input/output (I/O) ports. Each port has two digital I/O pins for a total of 8 digital I/O pins on an Expansion Hub. You will connect a REV Robotics Touch sensor to one of the digital I/O ports.

Note that in the case of the REV Robotics Touch Sensor, the device has a connector port for a 4-pin sensor cable. However, the device only needs to connect to one of the two available digital I/O pins. For the REV Robotics Touch Sensor, the second digital I/O pin in the port is the one that gets connected when a standard REV Robotics 4-pin JST PH cable is used. For the “0-1” port, it is the pin labeled “1” that gets connected through the 4-pin cable. Similarly, for the “2-3” port, it is the pin labeled “3” that gets connected through the 4-pin cable.

Note that it will take an estimated 2.5 minutes to complete this task.

Connecting a Touch Sensor to the Expansion Hub
1. Connect the one end of the 4-pin JST PH cable to the REV Robotics Touch sensor.

2. Plug the other end of the 4-pin JST PH cable to digital I/O port labeled “0-1” on the Expansion Hub.