* Read weight from a load cell using the ADS1230 IC in the LoadCell Nanoshield, with low gain.
*
* A low gain can be used when measuring weight over a wide range. To use a low gain the GAIN jumper
* in the LoadCell Nanoshield must remain open. This example uses averaging of 10 samples.
*
* Copyright (c) 2015 Circuitar
* This software is released under the MIT license. See the attached LICENSE file for details.
*/
#include <SPI.h>
#include <Nanoshield_LoadCell.h>
// LoadCell Nanoshield with the following parameters:
// - Load cell capacity: 100kg
// - Load cell sensitivity: 3mV/V
// - CS on pin D8 (D8 jumper closed)
// - Low gain (GAIN jumper open)
Nanoshield_LoadCell loadCell(100000, 3, 8, false);
void setup() {
Serial.begin(9600);
loadCell.begin();
// Wait for calibration and set current value to zero weight (tare)
while (!loadCell.updated());
loadCell.setZero();
}
void loop() {
if (loadCell.updated()) {
Serial.print(loadCell.getWeight(), 0);
Serial.println("g");
}
}