Test suite

The Expyriment test suite is a guided tool for testing your computer's abilities and performance. This includes timing accuracy of visual stimulus presentation, audio playback functionality, mouse functionality and serial/parallel port functionality.

Eventually, all test results can be saved as a protocol, together with some information about the system.

test_suite.png

Usage

Starting the test suite

The test suite can either be started from within an experiment, or from an interactive Python session (for instance with IPython). To start the test suite, just call:

import expyriment
expyriment.control.run_test_suite()

Alternatively, you can start the test suite from the command line using the :doc:`Command line interface <CommandLineInterface>`:

$ expyriment.cli -T

Please note that all changes to the :doc:`Defaults` prior to starting the test suite apply!

Menu overview

Here is a brief explanation of the available options:

  1. Visual stimulus presentation
  • Tests the visual stimulus presentation timing specifics of the system
The following results will be reported:
  • Estimated Screen Refresh Rate: The refresh rate of the screen in Hz and the approximated time of a single refresh in milliseconds. The most common refresh rate is arguably 60Hz (marked green), but specialised displays might also have refresh rates between 50 and 120 Hz (marked orange). Reported refresh rates outside of this range (marged red) are most probably erroneous.
  • Detected Framebuffer Pages: The amount of buffers used for drawing to the screen; if only one buffer is used, new stimuli will be drawn directly to the screen; if two buffers (double buffer) are used, new stimuli will be drawn to an additional page, and a screen update will replace the screen with this page and put the screen contents into the page (i.e. the two buffers are swapped); if three buffers (triple buffer) are used, new stimuli will be drawn to a third page, and a screen update will replace the screen with this page, and put the screen contents into the second page (i.e. a history of 2 former screens is kept)
  • Average Reporting Inaccuracy: The average time in milliseconds between Expyriment reporting that the stimulus has been presented (i.e. the present() method returns) and the actual time the stimulus could actually been physically shown on the screen, given the refresh rate; an inaccuracy of 0 milliseconds (marked green) will indicate that blocking on the vertical retrace functions properly; an inaccuracy of 1 millisecond or more (marked red) will indicate that blocking on the vertical does not function properly
  • Unexplained Presentation Delays: The amount in percent of presentations that will take longer than a single refresh rate
  • A histogram showing the obtained presentation timings
  1. Auditory stimulus presentation
  • Tests functionality of audio playback
  1. Font viewer
  • Test installed fonts
  1. Mouse test
  • Tests mouse accuracy (polling time)
  • Tests functionality of mouse buttons
  1. Parallel Port test
  • Tests functionality of devices connected via the parallel port
  1. Serial port test
  • Tests functionality of devices connected via the serial port
  1. Write protocol
  • Saves all test results, as well as information about the system, as a text file.
  1. Quit
  • Quits the test suite