3 changes: 1 addition & 2 deletions test/e2e/node_feature_discovery.go
Original file line number Diff line number Diff line change
Expand Up @@ -38,9 +38,8 @@ import (
e2elog "k8s.io/kubernetes/test/e2e/framework/log"
e2enetwork "k8s.io/kubernetes/test/e2e/framework/network"
e2epod "k8s.io/kubernetes/test/e2e/framework/pod"
nfdclient "sigs.k8s.io/node-feature-discovery/pkg/generated/clientset/versioned"

nfdv1alpha1 "sigs.k8s.io/node-feature-discovery/pkg/apis/nfd/v1alpha1"
nfdclient "sigs.k8s.io/node-feature-discovery/pkg/generated/clientset/versioned"
"sigs.k8s.io/node-feature-discovery/source/custom"
testutils "sigs.k8s.io/node-feature-discovery/test/e2e/utils"
)
Expand Down
45 changes: 24 additions & 21 deletions test/e2e/topology_updater.go
Original file line number Diff line number Diff line change
Expand Up @@ -28,14 +28,14 @@ import (
topologyclientset "github.com/k8stopologyawareschedwg/noderesourcetopology-api/pkg/generated/clientset/versioned"

corev1 "k8s.io/api/core/v1"
apiextensionsv1 "k8s.io/apiextensions-apiserver/pkg/apis/apiextensions/v1"
extclient "k8s.io/apiextensions-apiserver/pkg/client/clientset/clientset"
metav1 "k8s.io/apimachinery/pkg/apis/meta/v1"
"k8s.io/apimachinery/pkg/labels"
kubeletconfig "k8s.io/kubernetes/pkg/kubelet/apis/config"
"k8s.io/kubernetes/test/e2e/framework"
"k8s.io/kubernetes/test/e2e/framework/kubelet"
e2enetwork "k8s.io/kubernetes/test/e2e/framework/network"
admissionapi "k8s.io/pod-security-admission/api"

testutils "sigs.k8s.io/node-feature-discovery/test/e2e/utils"
)
Expand All @@ -44,14 +44,13 @@ var _ = SIGDescribe("Node Feature Discovery topology updater", func() {
var (
extClient *extclient.Clientset
topologyClient *topologyclientset.Clientset
crd *apiextensionsv1.CustomResourceDefinition
topologyUpdaterNode *corev1.Node
workerNodes []corev1.Node
kubeletConfig *kubeletconfig.KubeletConfiguration
)

f := framework.NewDefaultFramework("node-topology-updater")

f.NamespacePodSecurityEnforceLevel = admissionapi.LevelPrivileged
BeforeEach(func() {
var err error

Expand All @@ -72,7 +71,7 @@ var _ = SIGDescribe("Node Feature Discovery topology updater", func() {
By(fmt.Sprintf("Using config (%#v)", kcfg))

By("Creating the node resource topologies CRD")
crd, err = testutils.CreateNodeResourceTopologies(extClient)
_, err = testutils.CreateNodeResourceTopologies(extClient)
Expect(err).NotTo(HaveOccurred())

err = testutils.ConfigureRBAC(f.ClientSet, f.Namespace.Name)
Expand Down Expand Up @@ -209,32 +208,41 @@ var _ = SIGDescribe("Node Feature Discovery topology updater", func() {
initialNodeTopo := testutils.GetNodeTopology(topologyClient, topologyUpdaterNode.Name)
By("creating a pod consuming exclusive CPUs")
sleeperPod := testutils.GuaranteedSleeperPod("1000m")
// in case there is more than a single node in the cluster
// we need to set the node name, so we'll have certainty about
// which node we need to examine
sleeperPod.Spec.NodeName = topologyUpdaterNode.Name

podMap := make(map[string]*corev1.Pod)
pod := f.PodClient().CreateSync(sleeperPod)
podMap[pod.Name] = pod
defer testutils.DeletePodsAsync(f, podMap)

By("getting the updated topology")
By("checking the changes in the updated topology")
var finalNodeTopo *v1alpha1.NodeResourceTopology
Eventually(func() bool {
finalNodeTopo, err = topologyClient.TopologyV1alpha1().NodeResourceTopologies().Get(context.TODO(), topologyUpdaterNode.Name, metav1.GetOptions{})
if err != nil {
framework.Logf("failed to get the node topology resource: %v", err)
return false
}
return finalNodeTopo.ObjectMeta.ResourceVersion != initialNodeTopo.ObjectMeta.ResourceVersion
}, time.Minute, 5*time.Second).Should(BeTrue(), "didn't get updated node topology info")
By("checking the changes in the updated topology")
if finalNodeTopo.ObjectMeta.ResourceVersion == initialNodeTopo.ObjectMeta.ResourceVersion {
framework.Logf("node topology resource %s was not updated", topologyUpdaterNode.Name)
}

initialAllocRes := testutils.AllocatableResourceListFromNodeResourceTopology(initialNodeTopo)
finalAllocRes := testutils.AllocatableResourceListFromNodeResourceTopology(finalNodeTopo)
if len(initialAllocRes) == 0 || len(finalAllocRes) == 0 {
Fail(fmt.Sprintf("failed to find allocatable resources from node topology initial=%v final=%v", initialAllocRes, finalAllocRes))
}
zoneName, resName, isLess := lessAllocatableResources(initialAllocRes, finalAllocRes)
framework.Logf("zone=%q resource=%q isLess=%v", zoneName, resName, isLess)
Expect(isLess).To(BeTrue(), fmt.Sprintf("final allocatable resources not decreased - initial=%v final=%v", initialAllocRes, finalAllocRes))
initialAllocRes := testutils.AllocatableResourceListFromNodeResourceTopology(initialNodeTopo)
finalAllocRes := testutils.AllocatableResourceListFromNodeResourceTopology(finalNodeTopo)
if len(initialAllocRes) == 0 || len(finalAllocRes) == 0 {
Fail(fmt.Sprintf("failed to find allocatable resources from node topology initial=%v final=%v", initialAllocRes, finalAllocRes))
}

zoneName, resName, isLess := lessAllocatableResources(initialAllocRes, finalAllocRes)
framework.Logf("zone=%q resource=%q isLess=%v", zoneName, resName, isLess)
if !isLess {
framework.Logf("final allocatable resources not decreased - initial=%v final=%v", initialAllocRes, finalAllocRes)
}
return true
}, time.Minute, 5*time.Second).Should(BeTrue(), "didn't get updated node topology info")
})

})
Expand All @@ -244,11 +252,6 @@ var _ = SIGDescribe("Node Feature Discovery topology updater", func() {
if err != nil {
framework.Logf("failed to delete RBAC resources: %v", err)
}

err = extClient.ApiextensionsV1().CustomResourceDefinitions().Delete(context.TODO(), crd.Name, metav1.DeleteOptions{})
if err != nil {
framework.Logf("failed to delete node resources topologies CRD: %v", err)
}
})
})

Expand Down
22 changes: 17 additions & 5 deletions test/e2e/utils/noderesourcetopology.go
Original file line number Diff line number Diff line change
Expand Up @@ -35,6 +35,7 @@ import (
extclient "k8s.io/apiextensions-apiserver/pkg/client/clientset/clientset"
"k8s.io/apimachinery/pkg/api/errors"
metav1 "k8s.io/apimachinery/pkg/apis/meta/v1"
"k8s.io/apimachinery/pkg/util/wait"
"k8s.io/client-go/kubernetes/scheme"
kubeletconfig "k8s.io/kubernetes/pkg/kubelet/apis/config"
"k8s.io/kubernetes/test/e2e/framework"
Expand Down Expand Up @@ -81,15 +82,26 @@ func CreateNodeResourceTopologies(extClient extclient.Interface) (*apiextensions
return nil, err
}

updatedCrd, err := extClient.ApiextensionsV1().CustomResourceDefinitions().Get(context.TODO(), crd.Name, metav1.GetOptions{})
// Delete existing CRD (if any) with this we also get rid of stale objects
err = extClient.ApiextensionsV1().CustomResourceDefinitions().Delete(context.TODO(), crd.Name, metav1.DeleteOptions{})
if err != nil && !errors.IsNotFound(err) {
return nil, err
return nil, fmt.Errorf("failed to delete NodeResourceTopology CRD: %w", err)
}

if err == nil {
return updatedCrd, nil
}
// It takes time for the delete operation, wait until the CRD completely gone
if err = wait.PollImmediate(5*time.Second, 1*time.Minute, func() (bool, error) {
_, err = extClient.ApiextensionsV1().CustomResourceDefinitions().Get(context.TODO(), crd.Name, metav1.GetOptions{})
if err == nil {
return false, nil
}

if errors.IsNotFound(err) {
return true, nil
}
return false, err
}); err != nil {
return nil, fmt.Errorf("failed to get NodeResourceTopology CRD: %w", err)
}
return extClient.ApiextensionsV1().CustomResourceDefinitions().Create(context.TODO(), crd, metav1.CreateOptions{})
}

Expand Down
11 changes: 11 additions & 0 deletions test/e2e/utils/pod.go
Original file line number Diff line number Diff line change
Expand Up @@ -203,6 +203,8 @@ func newDaemonSet(name string, podSpec *corev1.PodSpec) *appsv1.DaemonSet {
}

func nfdWorkerPodSpec(image string, extraArgs []string) *corev1.PodSpec {
yes := true
no := false
return &corev1.PodSpec{
Containers: []corev1.Container{
{
Expand All @@ -221,6 +223,15 @@ func nfdWorkerPodSpec(image string, extraArgs []string) *corev1.PodSpec {
},
},
},
SecurityContext: &corev1.SecurityContext{
Capabilities: &corev1.Capabilities{
Drop: []corev1.Capability{"ALL"},
},
Privileged: &no,
RunAsNonRoot: &yes,
ReadOnlyRootFilesystem: &yes,
AllowPrivilegeEscalation: &no,
},
VolumeMounts: []corev1.VolumeMount{
{
Name: "host-boot",
Expand Down