Notifications
You must be signed in to change notification settings - Fork 112
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Signed-off-by: Dmitry Tantsur <dtantsur@protonmail.com>
- Loading branch information
Showing
3 changed files
with
171 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,169 @@ | ||
# RAID setup | ||
|
||
[RAID](https://en.wikipedia.org/wiki/RAID) is a technology that allows creating | ||
volumes with certain properties out of 2 or more physical disks. Depending on | ||
the [RAID level](https://en.wikipedia.org/wiki/Standard_RAID_levels), you may | ||
be able to merge several disks into a larger one or achieve redundancy. | ||
|
||
Metal3 supports two RAID implementation: | ||
|
||
- *Hardware RAID* is implemented by hardware itself and can be configured | ||
through the machine's BMC. | ||
- *Software RAID* is implemented by the Linux kernel and can be configured | ||
using the standard `mdadm` tool. | ||
|
||
To create or delete RAID volumes, you need to edit the `spec.raid` field of the | ||
`BareMetalHost` resource, changing either the `hardwareRAIDVolumes` or the | ||
`softwareRAIDVolumes` array. If the host is in the `available` state, it will | ||
be moved to the `preparing` state and the new settings will be applied. After | ||
some time, the host will move back to `available`, and the resulting changes | ||
will be reflected in its `status.raid` field. | ||
|
||
**Note:** RAID setup requires 1-2 reboots of the machine and thus may take 5-20 | ||
minutes. | ||
|
||
**Warning:** never try to configure both hardware and software RAID at the same | ||
time on the same host. While theoretically possible, this mode makes little | ||
sense and is not supported well by the underlying Ironic service. | ||
|
||
## Hardware RAID | ||
|
||
*Hardware RAID* is a type of RAID that is configured by a special component of | ||
the bare-metal machine - *RAID controller*. The resulting RAID volumes are | ||
normally presented transparently to the operating system and can be used as | ||
normal disks. | ||
|
||
Not all hardware models and Metal3 drivers support RAID: check [supported | ||
hardware](supported_hardware.md) for details. | ||
|
||
### Automatic allocation | ||
|
||
One approach is to define the required level, disk count and volume size, | ||
letting Ironic to automatically select the disks to place RAID on, for example: | ||
|
||
```yaml | ||
spec: | ||
raid: | ||
hardwareRAIDVolumes: | ||
- name: volume1 | ||
level: "5" | ||
numberOfPhysicalDisks: 3 | ||
sizeGibibytes: 350 | ||
``` | ||
The most common RAID levels are `0`, `1`, `5` and `1+0`. Levels `2`, `6`, | ||
`5+0` and `6+0` are also supported by Metal3 but may not be supported by all | ||
hardware models. The level dictates the minimum number of physical disks and | ||
the maximum size of a RAID volume. | ||
|
||
**Note:** because of values like `1+0`, RAID level is a string, not a number. | ||
|
||
You can use the boolean `rotational` field to filter out physical disks that | ||
are rotational (traditional hard drives) or not (SSD, NVMe). | ||
|
||
### Manual allocation | ||
|
||
Alternatively, you can provide the controller and a list of disk identifiers. | ||
Note that these are internal disk identifiers as reported by the BMC, not | ||
standard Linux names like `/dev/sda`. For example, on a Dell machine: | ||
|
||
```yaml | ||
spec: | ||
raid: | ||
hardwareRAIDVolumes: | ||
- name: volume2 | ||
level: "0" | ||
controller: RAID.Integrated.1-1 | ||
physicalDisks: | ||
- Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1 | ||
- Disk.Bay.6:Enclosure.Internal.0-1:RAID.Integrated.1-1 | ||
- Disk.Bay.7:Enclosure.Internal.0-1:RAID.Integrated.1-1 | ||
``` | ||
|
||
If you do not specify the size of the volume, the maximum possible size will be | ||
used (depending on size of the physical disks). | ||
|
||
### Removing RAID | ||
|
||
To remove the RAID configuration, set `hardwareRAIDVolumes` to an empty list: | ||
|
||
```yaml | ||
spec: | ||
raid: | ||
hardwareRAIDVolumes: [] | ||
``` | ||
|
||
**Warning:** there is a crucial difference between setting | ||
`hardwareRAIDVolumes` to an empty list and removing the `raid` field | ||
completely: the former will remove any existing volumes, the latter will not | ||
touch any existing RAID configuration. | ||
|
||
## Software RAID | ||
|
||
**Warning:** software RAID support is experimental. Please report any issues | ||
you encounter. | ||
|
||
*Software RAID* is configured by the `mdadm` utility from within the | ||
[IPA](../ironic/ironic-python-agent.md) ramdisk, which will be automatically | ||
booted by Ironic when the host moves to the `preparing` state. | ||
|
||
A subset of the hardware RAID API is provided for software RAID volumes with | ||
the following limitations: | ||
|
||
- The only supported levels are `0`, `1` and `1+0`. | ||
- Only one or two RAID volumes can be created on a host. | ||
- The first volume **must** have level `1` and should be used as the root | ||
device. | ||
- It is not possible to specify the number of physical disks. | ||
- The backing physical disks must not have any data or partitions on them. | ||
- Your instance image must have Linux software RAID support, including the | ||
`mdadm` utility. Other operating systems may not work at all. | ||
|
||
Check the [Ironic software RAID | ||
guide](https://docs.openstack.org/ironic/latest/admin/raid.html#software-raid) | ||
for more implementation details. | ||
|
||
### Software RAID: automatic allocation | ||
|
||
You can specify the sizes and the levels of the volume(s) and let Ironic do the | ||
rest. You can also omit the size of the last volume: | ||
|
||
```yaml | ||
spec: | ||
raid: | ||
softwareRAIDVolumes: | ||
- level: "1" | ||
sizeGibibytes: 10 | ||
- level: "0" | ||
``` | ||
|
||
**Note:** the same physical disks will be used for both volumes. Each physical | ||
disk will have partitions corresponding to each of the volumes. | ||
|
||
### Software RAID: manual allocation | ||
|
||
You can specify the backing physical disks using the same format as the | ||
`rootDeviceHints` field of the `BareMetalHost` resource, for example: | ||
|
||
```yaml | ||
spec: | ||
raid: | ||
softwareRAIDVolumes: | ||
- level: "1" | ||
physicalDisks: | ||
- serialNumber: abcd | ||
- serialNumber: efgh | ||
``` | ||
|
||
### Removing software RAID | ||
|
||
To remove the RAID configuration, set `softwareRAIDVolumes` to an empty list: | ||
|
||
```yaml | ||
spec: | ||
raid: | ||
softwareRAIDVolumes: [] | ||
``` | ||
|
||
**Warning:** even when [automated cleaning](automated_cleaning.md) is enabled, | ||
software RAID is not automatically removed on deprovisioning. |